Second Order Active Filters

From Mech
Revision as of 18:00, 8 December 2008 by StevenManuel (talk | contribs)
Jump to navigationJump to search

2nd order active filtering has two main advantages:

  • High impedance input, low impedance output
  • greater attenuation at high range (-40dB/decade as opposed to -20dB/decade for RC filter)

The high impedance provided by an op amp circuit protects the instrument providing the signal from passing excessive current which could cause a voltage drop in the measurement signal or damage to the instrument itself.

Because the filter is second order, the rolloff before/after the cutoff frequency or frequencies on a bode plot is -40 dB/decade as opposed to -20 dB/decade for a first order (RC) filter which means significantly greater attenuation outside the pass band and a sharper cutoff. This can be very useful if the noise frequency is close to the desired signal frequency.

2ndOrderFilterDiagrams.gif

Where the cutoff frequency for both high and low pass filters in Hz is: